Von Duprin 99 Parts Breakdown: Match the Symptom to the Replacement Part
Posted by National Lock Supply on Oct 16th 2026
Quick Verdict
Diagnose before ordering: most 99 failures trace to one of five assemblies. A rim device that will not retract usually needs the center case kit (050020 for non-fire rated 98/99 rim). A vertical rod device that will not latch or drags is usually rod adjustment, a worn latch, or the latch mounting bracket kit (050546 for 98/9927/9957). Dogging failures take a hex shaft or a cylinder dogging kit. Electrifying an existing 99 takes the 040066 QEL baseplate conversion kit for 4 ft devices. Every part is ordered by device type (rim, SVR, CVR), length (3 ft or 4 ft), fire rating (-F or not) and finish. When the chassis is cracked, the rail is bent or more than two assemblies are worn, replace the device. Never leave an exit device unable to release from the inside while waiting on parts.
What are the orderable parts of a Von Duprin 99?
The 99 is a modular device: a pushbar and rail, a center case with the mechanism, a latch (or top and bottom latches on rod devices), an end cap with the mechanism case, and dogging. Von Duprin sells most of these as kits, and the kit name tells you which device types it fits.
| Part | What it does | Symptom when it fails | Example part |
|---|---|---|---|
| Rim center case kit (less cover) | Houses the latch mechanism on rim devices | Latch will not retract, or retracts and sticks | 050020, 98/99 rim, non-fire rated |
| Center case kit, fire rated (less cover) | Same, for 98/9927 -F devices | Same, on fire-rated devices | 050021, 98/9927/-F |
| Latch mounting bracket kit | Holds top or bottom latch on SVR devices | Latch misaligned, door fails to latch | 050546, 98/9927/9957 |
| Vertical rods (SVR, CVR) | Connect center case to top and bottom latches | Device drags, bottom bolt scrapes, door will not latch | Extension rods by door height |
| Cylinder dogging kit | Lets a key hold the bar down | Dogging will not hold or will not release | 050115 for 33A and 99 |
| QEL conversion kit | Adds motorized latch retraction | Not a repair: an upgrade | 040066, 4 ft, 33A/35A and 98/99 |
Device architecture (rim vs SVR vs CVR vs mortise) matters for every row; read the rail and rods before ordering. If the question is whether the 98 or 99 is installed, the differences are in our Von Duprin 98 vs 99 buying guide.
Order the kit whose name lists your device type, then confirm fire rating and length.
Which part matches the symptom?
Work from symptom to assembly. Diagnose with the door in service condition; never wire, wedge or pin a device so it cannot release.
Latch will not retract when the bar is pushed (rim). The mechanism in the center case is worn or broken. The 050020 rim center case kit covers non-fire rated 98/99 rim devices and runs about $482 at NLS; it ships less cover, so reuse the existing cover. A fire-rated device takes the 050021 instead.
Door will not latch on close (rim). Check the strike first: a shifted frame or loose strike looks like a latch failure. If the latch bolt itself does not project fully, the center case is the part.
Door will not latch (SVR, 9927). Check rod adjustment and the top latch. The 9927 uses 1/2 in. square tubing rods, standard for 7 ft doors (top rod 34-15/16 in., bottom rod 31-1/2 in.), with deadlocking anti-friction top and bottom bolts of 5/8 in. throw. A latch that has walked out of position takes the 050546 latch mounting bracket kit, about $31 at NLS.
Bottom rod drags or bottom bolt scrapes (SVR, CVR). Von Duprin recommends a 1/4 in. door undercut on 9927 and 9947 devices. A door that has sagged on its hinges eats the undercut; fix hinges before blaming the rod. Von Duprin also builds 9927 versions with rod guards (RGO) for cart traffic.
Dogging will not hold. The hex shaft or the dogging mechanism is worn, or the cylinder cam is wrong on a CD device. Hex vs cylinder dogging and the kits for each are covered in hex dogging vs cylinder dogging.
End cap broken. End caps are series and finish specific. The 900981 end cap kit is listed for the 22 Series only and is a frequent mis-order on 99 devices; order the 99 end cap by finish and device type from the parts category.
Order the part named for the symptom from the Von Duprin parts and accessories category.
Which parts are length-specific or finish-specific?
The 99 comes in two lengths: 3 ft for 2 ft 4 in. to 3 ft doors and 4 ft for 2 ft 10 in. to 4 ft doors. Rail-length parts, such as the 4 ft 040066 QEL baseplate kit, must match the device.
Finish codes for 99 devices are 605, 606, 612, 625, 626/626AM, 628, 710, 711 and 643E. Von Duprin lists 619 and 630 as available on the 98 Series only, so a 630 part on a 99 is a sign the device is actually a 98.
Vertical rods depend on door height. The 9927 standard rods suit 7 ft doors, with 3 ft extension rods for taller doors and one-piece top rods for 8 ft and 10 ft doors. The 9947 concealed rod device uses round two-piece adjustable rods: top rod adjustable from 6 ft 8 in. to 8 ft 4 in., bottom rod from 35-5/8 in. to 49-5/8 in., with extension rod kits above 8 ft 4 in.
| Ordering field | Where to read it | Example |
|---|---|---|
| Device type | Rail profile, rods visible or concealed | 99 rim, 9927 SVR, 9947 CVR, 9975 mortise |
| Device length | Rail length or device label | 3 ft or 4 ft |
| Fire rating | Label on device, "-F" in part number | 9927EO-F takes the 050021 center case |
| Finish | Code stamped or on the schedule | 626, 628, 710 |
| Function | Trim on the pull side | EO (exit only), NL (night latch) |
| Door height (rod devices) | Measure the opening | 7 ft standard rods, extension above |
| Electrified options | Prefix on the device | QEL, RX, LX |
| Dogging | Hex hole or cylinder on rail | Hex key standard, CD for cylinder |
Prefix and suffix decoding is laid out in Von Duprin part numbers explained. Fill the table before calling in a part number.
How do you electrify an existing 99?
The 99 rail accepts quiet electric latch retraction as a conversion. The 040066 QEL baseplate conversion kit fits 4 ft 33A/35A and 98/99 devices, includes Allegion Connect, and is the conversion Von Duprin recommends when upgrading a solenoid-driven EL device. It runs about $1,017 at NLS.
QEL itself does not include the power transfer from door to frame, the power supply, or the control. Von Duprin specifies the PS902 or 914 with a 2RS, 4RL or 4R board as the minimum, and its low inrush lets it run on standard Schlage supplies once the peak draw of every device is calculated. The 114317-00 QEL modular conversion kit is listed as non-fire rated, so check the device label before using it on a fire door.
Third-party retrofit kits and factory QEL devices for every brand are compared in our ELR exit devices and retrofit kits guide. Electrical work belongs to a qualified technician, and the authority having jurisdiction (AHJ) governs fire-rated electrified openings.
When should you replace the whole device instead?
Replace rather than repair when any of these is true:
- The center case or chassis is cracked, or the rail is bent from cart impact.
- Two or more assemblies (center case plus latch, or latch plus rods) need replacement at once; kit prices add up fast against a complete device.
- The opening needs a function, rating or electrified option the existing device cannot take, such as converting non-fire rated hardware on a door now labeled for fire.
- The device is a 98 being fixed with 99 parts or vice versa.
For reference, a complete 9927EO surface vertical rod device runs about $1,838 at NLS. The cost logic is in repair vs replace commercial door hardware, and the install sequence for a new device is in our panic bar installation guide.
Price the complete device against the kit total, then order whichever is lower from the Von Duprin parts and accessories category.
Common mistakes
- Ordering the non-fire rated 050020 center case for a fire-rated device. Fire-rated 98/9927 devices take the 050021.
- Ordering the 900981 end cap kit for a 99. It is listed for the 22 Series.
- Replacing rods when the real problem is a sagging door eating the 1/4 in. undercut.
- Ordering a 4 ft QEL kit for a 3 ft device.
- Ordering 619 or 630 parts for a 99; those finishes are 98 only.
- Disabling or pinning a device to keep the door secure while parts are on order. Egress has to work at all times.
FAQ
What parts make up a Von Duprin 99? The pushbar and rail, the center case with mechanism, the latch (or top and bottom latches with rods on 9927 and 9947), the end cap and mechanism case, and dogging. Von Duprin sells center cases, latch brackets, dogging and conversion kits as separate parts.
Why is my panic bar not working? If the bar pushes but the latch stays out, the center case mechanism is the usual cause. If the door will not latch, check the strike, rod adjustment and latch bracket before ordering a center case.
Does the Von Duprin 22 end cap fit a 99? No. The 900981 end cap kit is listed for the 22 Series. Order the 99 end cap by device type and finish.
Can I add electric latch retraction to an existing 99? Yes. The 040066 QEL baseplate conversion kit fits 4 ft 33A/35A and 98/99 devices; power transfer, power supply and control are ordered separately.
Next step
Fill the ordering table, then order from the Von Duprin parts and accessories category: the 050020 rim center case kit, the 050546 latch mounting bracket kit or the 040066 QEL conversion kit. Orders by 3 p.m. ET ship the same day; $450 and up ships ground free. For a building-wide repair list, send it to the quote desk; agencies use government PO intake.
SAME DAY & EXPEDITED SHIPPING AVAILABLE