How a wall mount keypad controls a door

A wall mount keypad does not lock the door itself. It switches power to an electric locking device on the door, such as an electric strike, a maglock or an electrified exit device, when someone enters a valid code. That is the difference from a keypad lever lock, where the keypad, the lock and the batteries are all in the lockset. A wall keypad suits doors that already have, or will get, an electric lock and power, and it keeps the keypad electronics off the door.

Standalone keypads vs Wiegand keypads

Choose a standalone keypad when one keypad controls one or two doors on its own, and a Wiegand output keypad when the keypad feeds an access control panel. Standalone keypads hold the user codes and the relay in the unit or in a matching controller, for example the Securitron DK-16 and DK-26 (keypad and controller, 59 users) and the DK-12 (99 user codes). The SDC 918W is listed as an indoor Wiegand output keypad, which sends codes to a panel that makes the decisions.

KeypadTypeMountingUsers or notes (as listed)
Securitron DK-26Standalone, keypad and controllerNarrow stile, indoor/outdoor59 users; 12/24 VDC or VAC
Securitron DK-16Standalone, keypad and controllerSingle gang59 users
Securitron DK-12Standalone, illuminated keysSingle gang, indoor99 user codes; 12/24 VDC or VAC
Locknetics DKP-165, DKP-165-FM, DKP-165-SStandaloneSingle gang; flush or surface mountUp to 480 users, timed anti-pass back
Locknetics DKP-NSStandaloneOutdoorSee listing
Nortek Control 212I, 232IStandaloneIndoor flush mount212I: 120 users, 1 SPDT 2 amp relay
Nortek Control 212W, 212ILW, 212SE, 232SE, 212ILM, 212RStandalone, weather resistantFlush, surface, mullion, ruggedizedIndoor/outdoor
SDC 918U, 918W, 920, 920P, 926EntryCheck; 918W Wiegand outputIndoor or indoor/outdoor920P adds a prox reader
Nortek PROXPAD, PROX.PAD Plus; Alarm Controls KP-300Keypad with proximity or card readerSurface or mullion mountCode or credential entry

Indoor or outdoor: weather resistant keypads

A keypad on an exterior door must be rated for weather. The catalog marks weather resistant and outdoor models in their titles, such as the Nortek Control 212W, 212SE, 232SE, 212ILM and 212ILW, the SDC 920 and 926, the Locknetics DKP-NS and the Securitron DK-26, which is listed for indoor/outdoor use. For a single gang keypad outdoors, Securitron lists the WCC weather cover with single gang box and the WBB weather back box. The 212R is listed as ruggedized for abuse-prone locations.

Mounting options: single gang, flush, surface, mullion and narrow stile

Pick the keypad that fits the wall or frame beside the door. Single gang keypads fit a standard electrical box in the wall. Flush mount models sit in the wall, surface mount models sit on it, and mullion mount models are narrow enough for a storefront mullion. The Securitron DK-26 is designed for narrow stile aluminum frames, and the DK-CPSS is its single gang stainless steel cover plate.

Keypads with card or proximity readers

Some doors need both a code and a card, or either one. The Nortek PROXPAD and PROX.PAD Plus combine a keypad with a proximity reader (the Plus adds an integrated controller), the SDC 920P adds a prox reader to the EntryCheck keypad, and the Alarm Controls KP-300 is a mullion mount weather resistant keypad with a built-in card reader.

Power and wiring

Wall keypads run on low voltage from a power supply, and many accept AC or DC: the Securitron DK-12 and DK-26 are listed for 12 or 24 volts, AC or DC. The keypad's relay then switches the lock's power. Plan the power supply, the lock voltage and any request to exit device together; see access control power supplies and push to exit buttons.

Most requested keypads

The keypads our customers look up most often right now:

Related categories: commercial keypad and prox locks, electronic keypad locks and electric strikes.

What to have ready when ordering a door access keypad

  • The lock it will control (electric strike, maglock, exit device) and its voltage.
  • Standalone or connected to an access control panel (Wiegand).
  • Indoor or outdoor, and the mounting (single gang, flush, surface, mullion, narrow stile).
  • Number of users and whether you need a card or prox reader too.
  • Number of doors the keypad will control.

Planning several entries? Request a quote, and schools and agencies can submit a government or school PO. Orders placed before 3:00 p.m. ET on business days ship the same day after card approval, and ground shipping is free on orders of $450+. Call 718-814-6300 to plan the keypad, lock and power together.

The tables and selection notes on this page are compiled by National Lock Supply from manufacturer catalogs and product listings. Last reviewed: November 2026.

Frequently Asked Questions

Can you add a keypad to any door?

You can add a wall keypad to most doors, but the door also needs an electric locking device, such as an electric strike or a maglock, plus a power supply and wiring. The keypad switches power to that lock. If you do not want to run wiring, a battery-powered keypad lever lock is the alternative.

What are the downsides of keypad entry?

Codes can be shared or watched, and they need to be changed when staff leave. Keypads with more user codes let each person have their own code, which is easier to manage. Where higher security is needed, a keypad with a card or proximity reader, such as the SDC 920P or Nortek PROX.PAD Plus, adds a credential.

How many codes can a door keypad hold?

It depends on the model. The listings show 59 users on the Securitron DK-16 and DK-26, 99 user codes on the DK-12, 120 users on the Nortek Control 212I and up to 480 users on the Locknetics DKP-165. Choose a model with room for every user to have a personal code.