To factory reset a Schlage keypad lever or deadbolt (FE595, FE575, BE365), disconnect the battery, press and release the Schlage button, then within 10 seconds reconnect the battery and press and hold the Schlage button until it lights green and the lock beeps. This restores the default codes printed on the stickers, so locate them first. To change a code without resetting, enter the six-digit programming code and follow the add, delete, or chang… Read more