Push Button Egress Devices
A push to exit button releases an electric lock from the inside, so people can leave a door that is controlled by a maglock or card reader. Shop "Push to Exit" pushbuttons such as the Securitron EEB2 and SDC 422U, timed and pneumatic buttons, touchless and no-touch sensors, request to exit motion sensors, touch sense egress bars, keyswitches, and push plates for automatic door operators such as the BEA 10PBJ1.
What is a push to exit button?
A push to exit button is a switch mounted beside a door that cuts power to, or signals the release of, an electric lock when pressed, so the door can be opened from the inside. It is required where a door is locked by a maglock or another device that does not release from a lever or panic bar. Many buttons are labeled "Push to Exit" or "Exit", and some include a timer that keeps the door unlocked for a set time after release.
The two jobs: egress release vs request to exit signal
Egress devices in this category do one of two jobs, and some do both. An egress release (push to exit) removes power from the lock so the door opens. A request to exit (REX) signal tells the access control system that someone is leaving, so it does not report a forced door. Motion sensors such as the Schlage Electronics Scan II passive infrared detector and the Alarm Controls SREX-100 are designed for request to exit, and the Securitron EEB2 emergency exit button is listed as a redundant backup next to the door for use with the XMS motion sensor.
Types of egress devices in the catalog
| Type | Examples | Notes from the listing |
|---|---|---|
| Push to exit pushbuttons | Securitron PB, PB2, PB3, PB5, EEB2, EEB3N; SDC 422U; RCI 908, 918-RE; Alarm Controls TS-2; DynaLock 6115M | Illuminated or not, momentary or alternate action, single gang or narrow stile |
| Timed buttons | SDC 423U (1 to 60 sec adjustable), 423MU and 413MNU (fixed 30 sec); RCI 991-REPTD pneumatic (2 to 45 sec); Camden CM-30EE (30 sec) | Keep the lock released for a set time |
| Touchless and no-touch sensors | SDC 474U, 474MU, 474DU; Alarm Controls NTB-1A, NTB-2, NTB-3; RCI 910TC, 912-WBT; Camden SureWave CM-324, CM-325, CM-333; Securitron WSS-WSD | Wave to release; some battery powered |
| Request to exit motion sensors | Schlage Electronics Scan II; Alarm Controls SREX-100; RCI 913 microwave, 915 passive infrared | Detect a person approaching the door |
| Egress bars and touch handles | Securitron TSB, DSB, EMB, WEMB, TSH, EMH, EL-EMH; SDC MSB550, PSB560V | Touch sense, dual sense, mechanical and pressure sense |
| Keyswitches and palm switches | SDC 701U, 702U, 701NU; DynaLock 6210, 6220, 6230 | Key or palm operation |
| Automatic operator push plates | BEA 10PBS, 10PBR, 10PBJ, 10EMS, 10EMR; Camden CM-45/4, CM-46/4, CM-25/4, CM-7536/4; RCI 940HP-MO, 950 | "Push to Open" text and accessibility logo options; wireless versions |
Momentary vs alternate action buttons
A momentary button releases the lock only while it is pressed, or for the timer period, and then the door relocks. An alternate action button toggles: press once to unlock and again to lock. Exit buttons on egress doors are normally momentary or timed. Securitron lists both, for example the PB3E momentary and PB3EA alternate action buttons, and the SDC 701U keyswitch is alternate action while the 702U is momentary.
What height should a push to exit button be?
For access-controlled egress doors, NFPA 101 and the International Building Code describe a manual release labeled "PUSH TO EXIT" mounted 40 to 48 inches above the floor and within 5 feet of the door, which removes power to the lock directly and keeps it unlocked for at least 30 seconds. Requirements vary by code edition and occupancy, so confirm the mounting height, timer and wiring with your local authority. Timed buttons such as the SDC 423U and the fixed 30-second SDC 423MU are designed for this kind of release.
Push plates for automatic door operators
Push plates with "Push to Open" text and an accessibility logo activate an automatic door operator, which is a different job from releasing a lock. BEA lists square, round and jamb stainless steel push plates and Panther plates, including wireless 900 MHz versions, and Camden lists 4-1/2" square, narrow and 36" column push plate switches, including kinetic wireless transmitters. Pair the plate with the operator's receiver and wiring.
Most requested egress devices
The egress devices our customers look up most often right now:
- BEA 10PBJ1 Stainless Steel Jamb Push Plate
- Securitron EEB2 Emergency Exit Button, Single Gang
- RCI 991-REPTD Pneumatic Time Delay Pushbutton
- SDC 423U Push to Exit Button with Adjustable Timer
Related categories: maglocks, access control power supplies, door access keypads and electronic door hardware.
What to have ready when ordering a push to exit button
- The lock it releases (maglock, electric strike) and its voltage.
- Release only, request to exit signal, or both (contacts: SPDT or DPDT).
- Momentary, alternate action or timed, and the timer range needed.
- Mounting: single gang, double gang, narrow stile or surface, indoor or outdoor.
- Label and color: "Push to Exit", "Exit", red or green, illuminated or not.
Wiring several doors? Request a quote, and schools and agencies can submit a government or school PO. Orders placed before 3:00 p.m. ET on business days ship the same day after card approval, and ground shipping is free on orders of $450+. Call 718-814-6300 to match the button to the lock.
The tables and selection notes on this page are compiled by National Lock Supply from manufacturer catalogs and product listings. Last reviewed: November 2026.
Frequently Asked Questions
Does a maglock need a push to exit button?
In most cases, yes. A maglock does not release when someone turns a lever or pushes a bar, so the door needs a way to remove power from inside, such as a push to exit button, a motion sensor or an egress bar. Codes for access-controlled egress doors set the details.
What is the difference between push to exit and push to open?
"Push to Exit" buttons release an electric lock so a person can leave. "Push to Open" plates, usually with an accessibility logo, activate an automatic door operator that swings the door open. BEA and Camden push plates in this category are designed for automatic operators.
What is a touchless exit switch?
A touchless exit switch releases the door when a hand is waved in front of it, without contact. Examples are the SDC 474U, Alarm Controls NTB-1A, RCI 912-WBT and Camden SureWave switches. Some, such as the SDC 474MU, add a manual override button.
Can a push to exit button have a timer?
Yes. The SDC 423U has an electronic timer adjustable from 1 to 60 seconds, the SDC 423MU and 413MNU have a fixed 30-second timer, the RCI 991-REPTD is a pneumatic time delay button rated 2 to 45 seconds and the Camden CM-30EE has a fixed 30-second timer.