Skip to main content

FREE SHIPPING ALL ORDERS $450 AND UP!

SAME DAY & EXPEDITED SHIPPING AVAILABLE

Von Duprin/Schlage PS904-4R Base Power Supply (4A @ 12/24 VDC- field selectable) w/ 4 Independently Controlled Relays

In Stock
$616.90
Price: $952.00
Instant Savings $335.10

FREE SHIPPING

SKU: PS904-4R
Series: PS900
Amperage: 4 amps
Choose Options:
Hurry! Only left

Von Duprin/Schlage PS904-4R Base Power Supply (4A @ 12/24 VDC- field selectable) with Independently Controlled Relays 

Description:
PS904 is able to accept a total of two optional distribution boards, plus one battery backup board and up to two 7A/hr batteries

Applications
The PS900 Series of power supplies works with many electrified devices including Schlage electromagnetic locks, Schlage AD Series hardwired locks, Schlage electrified mechanical locks, Von Duprin electrified strikes,
Von Duprin exit devices, and many other brands.

Overview
The Schlage comprehensive line of power supplies and option boards was designed to address the changing needs of the access control market. Installation is simplified by utilizing a flat mounting design and polarized locking connectors for option boards. This design eliminates the need for racks and side connectors. The flat mounting of the option boards also provides for easier access to the terminal blocks for connection of electrified devices (such as electrified strikes, electromagnetic locks, card
readers, etc.).

Common to the line of PS900 Series power supplies is a constant output rating at both 12v and 24v settings, universal 120 VAC to 240 VAC input, and polarized option board connectors. New fire alarm interface board mounting allows outputs to be configured as switched (power cut) or unswitched (power continues) when signal is provided.

900-4R Specifications
4 Independently Controlled Relays

Inputs I1,I4
Dry contacts required (Closed = Active)
Connect control contacts between SC (Signal Common) and any input

Outputs O1,O4
• Form C contacts rated 30VDC, 3A (Dry)
• 12/24VDC, 3A (Wet) when AC powered
• 9.6-13.2VDC or 19.2-26.4VDC when battery powered
• Maximum load cannot exceed power supply ratings or 6A for outputs combined

Board Input Power: Board requires 0.18A max. of power supply output current to operate

Temperature Range: 32°-120° F (0°- 49° C)

Compliance: UL 294, ULC-S318, RoHS, & FCC Part 15

PS904 Features and Benefits
• 4A @ 12/24 VDC constant output, field selectable with jumper
• Provides low-voltage, Class 2, filtered and regulated power
• Universal 120-240 VAC, fused primary input
• Two polarized option board connectors eliminate need for racks and side connectors
• AC input and DC output monitoring circuit with LED indicators
• Externally visible AC input indicator with isolated SPDT contacts
• High-voltage protective cover for AC circuitry (not shown)
• Battery back-up board auto-selects voltage
• Optional Fire Alarm plug-in board available
• UL 294, ULC-S318, RoHS, and FCC Part 15 certified

Specifications
Input voltage: 120/240 VAC, 50/60 Hz, universal input

Output voltage: 4A @ 12 or 24 VDC Field selectable with jumper. Switching supply, 5% regulation, 240mVpp max ripple

Enclosure: Grey/baked enamel 14" x 12" x 4" (H x W x D). Eight 1⁄2" x 3⁄4" knockouts NEMA Grade 1. Hinged cover with lock down screws

Operating temperature: 32°-120°F (0°-49°C)

AC primary fuse size: 4A, 250v, 5 x 20mm

Battery fuse size: 7.5A 32v ATO blade style

DC output protection: Overload protection—current limited foldback circuit

AC input termination: 3 position terminal block with protective cover; Wire capacity: 10 AWG max.

DC output termination: 2 position terminal block; Wire capacity: 12 AWG max

Option board connectors: 2

Optional board
FA - Plug-in fire alarm (must be installed on option board)

Model: Von Duprin/Schlage PS904-4R, PS904-4R-FA

Free Ground Shipping

orders $450 and up

Easy Returns

no question asked

Quantity Discounts

request a quote

Outstanding Customer Service