FREE SHIPPING ALL ORDERS $450 AND UP!
SAME DAY & EXPEDITED SHIPPING AVAILABLE
Von Duprin PS914-2RS Base Power Supply (4A (16A inrush) @ 12/24 VDC Field Selectable) with 2 Relay Board Output
Description: PS914 is able to accept a total of two optional boards, plus one battery backup board and two 7A/hr batteries
Applications
The PS900 Series of power supplies works with many electrified devices including Schlage electromagnetic locks, Schlage AD Series hardwired locks, Schlage electrified mechanical locks, Von Duprin electrified strikes, Von Duprin exit devices, and many other brands.
Overview
Von Duprin power supply and option board products were designed to meet the specific requirements of electrified fire exit devices. Installation is simplified by utilizing a flat mounting design and polarized locking connectors for option boards. This design eliminates the need for racks and side connectors. The flat mounting of the option boards also provides for easier access to the terminal blocks for connection of electrified devices (such as electrified panic devices, strikes, card readers, etc.).
Common to the line of PS900 Series power supplies is a constant output rating at both 12v and 24v settings, universal 120 VAC to 240 VAC input, and polarized option board connectors. New fire alarm interface board mounting allows outputs to be configured as switched (power cut) or unswitched (power continues) when signal is provided.
900-2RS Specifications
2 Relay option board capable of individual or sequential operation for single and pair door applications.
Inputs I1,I2
Dry contacts required (Closed = Active)
Connect control contacts between SC (Signal Common) and any input
Outputs O1,O2
• 12/24VDC, 3A (wet) when AC powered
• 9.6-13.2VDC or 19.2-26.4VDC when battery powered
• May be used with PS914 to power EL device at 24VDC, 16A, 300ms
• Maximum load cannot exceed power supply ratings or 3A for outputs combined
Board Input Power: Board requires 0.1A max. of power supply output current to operate
Temperature Range: 32°-120° F (0°- 49° C)
Compliance: UL 294, ULC-S318, RoHS, & FCC Part 15
PS914 Features and Benefits
• 4A @ 12/24 VDC constant output, field selectable with jumper
• Designed for use with electrified panic devices requiring high in rush current
• Provides low-voltage, Class 2, filtered andregulated power
• Universal 120-240 VAC, fused primary input
• Two polarized option board connectors
• AC input and DC output monitoring circuit with LED indicators
• Externally visible AC input indicator with isolated SPDT contacts
• High-voltage protective cover for AC circuitry
• Battery back-up board auto-selects voltage
• Optional Fire Alarm plug-in board available
• UL 294, ULC-S318, RoHS, and FCC Part 15 certified
Specifications
Input voltage: 120/240 VAC, 50/60 Hz, universal input
Output voltage: 4A @ 12 or 24 VDCField selectable with jumper. Switching supply, 5% regulation, 360mVpp max ripple
Enclosure: Grey/baked enamel 14" x 12" x 4" (H x W x D). Eight 1⁄2" x 3⁄4" knockouts. Hinged cover with lock down screws
Operating temperature: 32°- 120°F (0°- 49°C)
AC primary fuse size: 6.3A, 250v, 5 x 20mm
Battery fuse size: 7.5A 32v ATO blade style
DC output protection: Overload protection - current limited foldback circuit
AC input termination: 3 position terminal block with protective cover; Wire capacity: 10 AWG max.
DC output termination: 2 position terminal block; Wire capacity: 12 AWG max.
Optional boards
FA - Plug-in fire alarm (must be installed on option board)
BBK - Battery backup kit (backup board plus battery pack)
FA-BBK - Plug-in fire alarm and Battery backup kit
Model: Von Duprin PS914-2RS, PS914-2RS-FA, PS914-2RS-BBK, PS914-2RS-FA-BBK