FREE SHIPPING ALL ORDERS $450 AND UP!
SAME DAY & EXPEDITED SHIPPING AVAILABLE
Falcon F-25-C-EO 32D Fire Rated Concealed Vertical Rod Heavy Duty Exit Device 25 Series, Exit Only, 3 Ft. Device, Satin Stainless Steel Finish
Specifications
Device functions: EO - Exit Only
Device lengths:
3' For Doors Up to 36" Wide - Min door opening width: 2' 7 1⁄8"
Dogging Options: Less Dogging
Door Stile: 4" (6 1⁄2" for wood doors)
Handing: Field reversible
Strikes: 4188 mortised top, 2130 bottom standard
Latchbolt: Stainless steel, 3⁄4" throw.
Deadlocking latchbolt: Standard
Projections: 2 3⁄4" maximum
Fasteners: All mounting screws are concealed. All machine screws (AMS) standard.
Vertical rods: Furnished to length based on 40 1⁄4" horizontal CL to finished floor and a 7'0" door.
ANSI: Certified ANSI A156.3-2001 grade 1 standards.
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619); US19 (622); US26 (625); US26D (626); US32 (629); US32D (630);
US28 (628), 313AN (710)
Motorized electric latch retraction can be used with credential readers to unlatch doors momentarily for authorized users,
or it can be incorporated with systems to retract latches for extended periods of time to allow free entry. This is a convenient alternative
to mechanical dogging. Doors with automatic operators also may use exit devices with electric latch retraction.
The MEL option is available on panic and fire rated devices. Because fire exit hardware must be self latching, an automatic
fire alarm system must be incorporated to drop power to fire rated MEL devices in case of fire.
Device Monitoring
RX Monitoring
The RX feature monitors the depression of the touch bar or crossbar. Activation of the switch indicates use of a door
or that the door is in the dogged condition. This feature is especially useful when used to activate or shunt magnetic
locking systems.
Features and benefits
• Energy efficient motorized latch retraction enables longer wire runs and the use of a standard Schlage power supply with option board
• Modular design allows for a simplified installation of the available MEL Conversion kit to existing mechanical Falcon 24 or 25 exit devices
• On-board installation and troubleshooting diagnostics built into the motor assembly
• Self-calibrating motor assembly
• Pushbar is pulled in electronically when dogged
• Vandal resistant – detects and responds to events of attack and tampering
MEL system requirements
The MEL has a low inrush current = 1.0 amps, so it can be used with standard Schlage power supplies. When powering multiple
components, verify that the amperage requirement of all components combined does not exceed the power supply output rating.
The MEL device is compatible with the following equipment: PS900 Series power supplies - PS902, 904, 906, 914; 900 Series
Option Boards - 900-2RS, 900-4R and 900-4RL
A power transfer (EPT, electrified hinge, or door loop) is required and sold separately
Model: Falcon F-25-C-EO 3 32D