Accentra (Yale) Parts and Accessories
Accentra (Yale) panic bar parts keep Yale 7000 Series exit devices working without replacing the whole device. Find latch and bracket assemblies, top and bottom rods, bolt cases, the 757F rim strike, floor strikes, end cap kits, the 715-48 cylinder dogging kit and the 988Y surface bolt kit. Complete devices are in Accentra (Yale) exit devices.
Accentra and Yale: the same exit devices
Accentra is the name now used for the commercial hardware that was sold as Yale, so the product listings in this category read "Accentra (Yale)". The parts are the same Yale part numbers, and the Yale 7000 Series parts manual still applies. If your device says Yale on the label, these are the right parts.
Find the part by device model
Most parts in this category are for the 7000 Series, and each listing states the device models it fits. Read the model on the device (for example 7100, 7200M or 7220M) and check the "for use with" line on the listing before ordering. A suffix F on a model, such as 7170F or 7160(F), indicates the fire rated version, and some parts are listed only for fire rated devices.
| Part | Part number | Fits (as listed) |
|---|---|---|
| Rim strike | 757F | 1800(F), 2100(F), 6100(F), 7100(F), 7180(F); used with 7100(F), 7150(F), 7200M(F), 7250M(F) |
| Top latch and bracket assembly | 60-7020-0057-000 | 7120, 7220M |
| Fire rated upper latch and bracket | 60-7020-0060-000 | Fire rated devices |
| Top latch and bracket | 60-7160-0060-000 | 7160(F) |
| Latch assembly | 60-7010-0360-048 RHR | 7170, 7170F |
| Latch case assembly | 60-7200-0354-048 | 7200, 7200M |
| Latch assembly covers | 60-7000-X111-630, 60-7000-X353-630 | 7200, 7200M; 7220, 7220M |
| Mortise lock body or assembly | 60-7030-0391-048, 60-7030-0393-048 | 7130-L5F, 7130-L8F |
| Rods, bolt case, rod guide cover | 60-7010-7052-033 top rod, 60-7010-0020-033 bottom rod, 60-7010-0054-000 bottom bolt case, 60-7010-7051-033 rod guide cover | 7000 Series |
| Floor strikes | 790, 702 | 7000 Series; 702 for bottom Pullman latch option |
| End caps | ECK7-630, 81-9500-0620-630 flush end cap kit | 7000 Series; satin stainless steel |
| Dogging, surface bolt and fire kits | 715-48 cylinder dogging kit, 988Y surface bolt kit, 60-7110-0002-999 popper packet | 48" device; 7000 Series; fire rated only |
Rim strikes and floor strikes
A worn or misaligned strike is a common reason a Yale panic bar will not latch. The 757F rim strike is listed for 1800, 2100, 6100, 7100 and 7180 devices, including fire rated versions, and measures 1-1/4" wide, 11/16" thick and 3-1/2" high according to the listing. For vertical rod devices, the 790 is a 7000 Series floor strike and the 702 is the floor strike for the bottom Pullman latch option.
Vertical rod parts: latches, rods and bolt cases
Vertical rod devices latch at the top and bottom of the door, so wear shows up in the latches, rods and bolt cases. The catalog lists the top latch assembly (60-7010-0049-999), top latch and bracket assemblies for the 7120, 7220M and 7160(F), the top rod, bottom rod assembly, bottom bolt case and rod guide cover. Measure the door height and confirm surface or concealed rods before ordering rods.
Cylinder dogging, surface bolts and end caps
The 715-48 converts a 48" device to cylinder dogging (less cylinder), so the latch can be held retracted with a key instead of a hex key. The 988Y surface bolt kit is a field install kit for the 7000 exit device. End caps are listed as the ECK7-630 end cap kit and the 81-9500-0620-630 flush end cap kit in satin stainless steel.
Yale 311N and older Yale devices
We get many searches for Yale 311N panic bar parts. The parts in this category are for the Yale 7000 Series and the devices named in each listing, and we do not currently list 311N parts. If you have a 311N or another older Yale device, send us the device label or the part number and we will check what is available or suggest a replacement device.
Yale 7000 Series parts manual
Use the Yale 7000 exit device parts manual (PDF) and the Yale 7000 Series catalog (PDF), hosted on our product pages, to find the exact part number in the exploded diagrams.
Most requested Accentra (Yale) parts
The Yale exit device parts our customers look up most often right now:
- Accentra (Yale) 757F Rim Exit Device Strike
- Accentra (Yale) 988Y Surface Bolt Kit
- Accentra (Yale) 60-7000-X353-630 Latch Assembly Cover for 7220, 7220M
- Accentra (Yale) 60-7020-0057-000 Upper Latch and Bracket Assembly
- Accentra (Yale) 60-7200-0354-048 Latch Case Assembly for 7200, 7200M
Shop by model: 715-48 cylinder dogging kit.
Related categories: Yale 7000 Series exit devices, Yale 2100 Series exit devices, exit device trims and Accentra (Yale) exit devices.
What to have ready when ordering Yale panic bar parts
- Device model from the label, including any F (fire rated) or M suffix.
- Device type: rim, surface vertical rod, concealed vertical rod or mortise.
- Device size (for example 48") for dogging kits, and door height for rods.
- Hand (for example RHR) for handed latch assemblies.
- Finish, such as 630 satin stainless steel.
Servicing several exits? Request a quote, and schools and agencies can submit a government or school PO. Orders placed before 3:00 p.m. ET on business days ship the same day after card approval, and ground shipping is free on orders of $450+. Send us your device model and part number: call 718-814-6300.
The tables and selection notes on this page are compiled by National Lock Supply from the Yale 7000 Series parts manual, catalog and product listings. Last reviewed: November 2026.
Frequently Asked Questions
What does the F mean on a Yale exit device model?
An F after the model number, as in 7170F or 7160(F), indicates the fire rated version of the device. Some parts are listed only for fire rated devices, such as the 60-7020-0060-000 fire rated upper latch and bracket assembly and the 60-7110-0002-999 popper packet.
Are Yale exit device parts handed?
Many Yale exit device parts, such as rim strikes, rods and end caps, are non-handed, while some trims and conversion parts are handed. Check the listing, and if your device is labeled for a left hand or right hand reverse bevel door, match that hand when the part is handed.
Should I repair an old Yale exit device or replace it?
If only a strike, end cap or dogging part has failed, repair is usually the faster option. When the device is an older model whose parts are no longer made, such as many Yale 311N parts, replacing the complete device is often more practical. Measure the door width and stile and note the strike location before you order.
SAME DAY & EXPEDITED SHIPPING AVAILABLE