Corbin Russwin CL3355 PZD Extra Heavy-Duty Classroom Cylindrical Lever Lock
Function Description: Classroom - ANSI No. F84
• Deadlocking latchbolt by lever either side, except when key outside locks outside lever. (Lever handle is freewheeling in locked position.)
• Outside lever unlocked by key outside.
• Inside lever always free.
Handing: Non-handed
Door Thickness: 1-3/4" (44mm) - 2" (51mm) standard.
Door Prep: ANSI/BHMA A156.115
Lock Chassis: Steel, zinc dichromated for corrosion resistance.
Backset: 2-3/4" (70mm) backset w/ 1-1/8" front (standard)
2-3/8" (60mm) backset w/ 1" wide front
Bearing Assembly: Cast and machined stainless steel
Latchbolt: Stainless Steel, 1/2" (13mm) throw. Optional: 3/4" (19mm) throw deadlocking fire latch for pair of doors.
Auxiliary Latchbolt: Deadlocking latchbolt prevents manipulation when door is closed.
Front: Wrought brass or stainless steel, 2-1/4" (57mm) x 1-1/8" (29mm).
Accommodates flat front doors and doors beveled 1/8" (3mm) in 2" (51mm).
Strike: Wrought brass or stainless steel ANSI curved lip standard, 4-7/8" (124mm) x
1-1/4" (32mm) x 1-1/4" (32mm) lip to center.
Levers: Secured with 6 lobe security set screw standard
Roses: Brass
Cylinder: Brass, 6-pin L4 keyway,
Keying Features Available:
Master keying, Construction master keying, Visual key control, Concealed key control,
Interchangeable core (LFIC or SFIC), Security, Security LFIC, Access 3® LFIC, Pyramid, Pyramid LFIC
Keys: Two nickel silver standard.
Warranty: Ten-year limited.
Certification/Compliance:
ANSI/BHMA
Certified ANSI/BHMA A156.2 (2017) Series 4000 — Grade 1
Certified ANSI/BHMA A156.41
UL/cUL
UL/cUL listed to US and Canadian safety standards for 3 hour doors up to 4' x 10' (double doors require 41- option)
NFPA 80
Conforms for life safety and property protection, Standard for Fire Doors and Other Opening Protectives
Positive Pressure
Meets ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies
ADA
All levers conform to ADA clear opening width requirements of ANSI A117.1
California State Reference Code (Formerly Title 19, California State Fire Marshal Standard)
All levers with returns comply; levers return to within 1/2" (13mm) of door face
Windstorm/Hurricane
All individual components of a total door opening are required to comply with each code.
Model: Corbin Russwin CLX3355 PZD 626, CLX3355 PZD 605, CLX3355 PZD 606, CLX3355 PZD 612, CLX3355 PZD 613, CLX3355 PZD 625, CLX3355 PZD 626 M08, CLX3355 PZD 605 M08, CLX3355 PZD 606 M08, CLX3355 PZD 612 M08, CLX3355 PZD 613 M08, CLX3355 PZD 625 M08, CLX3355 PZD 626 CL6, CLX3355 PZD 605 CL6, CLX3355 PZD 606 CL6, CLX3355 PZD 612 CL6, CLX3355 PZD 613 CL6, CLX3355 PZD 625 CL6, CLX3355 PZD 626 LC, CLX3355 PZD 605 LC, CLX3355 PZD 606 LC, CLX3355 PZD 612 LC, CLX3355 PZD 613 LC, CLX3355 PZD 625 LC