FREE SHIPPING ALL ORDERS $450 AND UP!
SAME DAY & EXPEDITED SHIPPING AVAILABLE
Corbin Russwin CL3310 PZD Extra Heavy-Duty Passage or Closet Lever Set
Function Description: Passage or Closet - ANSI F75
• Latchbolt by lever either side.
• Both levers always free.
Handing: Non-handed
Door Thickness: 1-3/4" (44mm) - 2" (51mm) standard. Optional: Over 2" (51mm) - 2-1/4" (57mm)
Door Prep: ANSI/BHMA A156.115 (161)
Lock Chassis: Steel, zinc dichromated for corrosion resistance.
Backset: 2-3/4" (70mm) standard. Optional: 3-3/4" (95mm) and 5" (127mm)
Bearing Assembly: Cast and machined stainless steel
Latchbolt: Stainless Steel, 1/2" (13mm) throw. Optional: 3/4" (19mm) throw deadlocking fire latch for pair of doors.
Auxiliary Latchbolt: Deadlocking latchbolt prevents manipulation when door is closed.
Front: Wrought brass or stainless steel, 2-1/4" (57mm) x 1-1/8" (29mm).
Accommodates flat front doors and doors beveled 1/8" (3mm) in 2" (51mm).
Strike: Wrought brass or stainless steel ANSI curved lip standard, 4-7/8" (124mm) x
1-1/4" (32mm) x 1-1/4" (32mm) lip to center.
Optional: strikes, lip lengths and ANSI wrought strike box available.
Levers: Secured with 6 lobe security set screw standard
Roses: Brass
Warranty: Seven-year limited.
Certification/Compliance:
ANSI: Meets A156.2 Series 4000, Grade 1.
Meets A117.1 Accessibility Code.
Federal: Meets FF-H-106C.
California State Reference Code: (Formerly Title 19, California State Fire
Marshal Standard) All levers with returns comply; levers return to within 1/2" (13mm) of door face.
C-UL US: All locks with 1/2" (13mm) throw latchbolt listed for A label and lesser class 4' x 10' single doors. All locks with 3/4" (19mm)
throw latchbolt listed for A label and lesser class 8' x 10' pairs of doors. Letter F and UL symbol on latch front indicate listing.
Any retrofit or other field modification to a fire-rated opening can potentially impact the fire-rating of the opening, and Corbin
Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing firerated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
Model: Corbin Russwin CL3310 PZD 626, PZD 605, PZD 606, PZD 612, PZD 613, PZD 625